Archives

GRI White Paper #10/Test Method GTI2(A)

October 1st, 2015

Flammability? Zip ties? MARV? Ponds? GT specs? Questions and answers from the GMA Techline. I have reviewed GRI White Paper #10, GRI Test Method GT12(a), ASTM D4354, and ASTM D4759 and have a question. I have reviewed some recent CQA test results of a nonwoven cushion geotextile roll sample and while the average of the […]

Read More

Nonwoven needle-punched GT

October 1st, 2015

We specify that the geotextile under riprap must be nonwoven, needle-punched, Class 1. NCHRP Report 568 (page C-25, Section 7.1) requires that nonwoven geotextile filter under riprap must have a mass density greater than 12osy (ounces per square yard). We have the following questions: What is the cost difference between nonwoven needle-punched, Class 1 12osy […]

Read More

Effluent pond liners

October 1st, 2015

Flammability? Zip ties? MARV? Ponds? GT specs? Questions and answers from the GMA Techline. I’m designing an effluent pond (the geotechnical aspect at least) and have a couple of questions: Do you see any issues with placing a gravel (rounded) subdrain system underneath the pond, sandwiched between a geomembrane (likely textured HDPE) and a geotextile […]

Read More

GCL woven side against geomembrane

October 1st, 2015

Flammability? Zip ties? MARV? Ponds? GT Specs? Questions and answers from the GMA Techline. I seem to recall a webinar or presentation in which the presenter warned against using the woven side of a GCL against a geomembrane due to bentonite squeeze-out and subsequent slippage. Instead, the nonwoven side was recommended against the geomembrane with […]

Read More

HDPE flammability

October 1st, 2015

Flammability? Zip yies? MARV? Ponds? GT specs? Questions and answers from the GMA Techline. I am involved with a landfill permit renewal. A question keeps coming up concerning the flammability potential of HDPE liner. What is that potential and do you know of any liner system fires? Eric | USA Eric, HDPE melts between 110 […]

Read More