This page was printed from https://geosyntheticsmagazine.com

GM19, Revision 7—Peel separation 5 out of 5?

News | June 1, 2014 | By:

I am looking for a discussion of how peel separation % in the latest revision of GM19 went from 4 out of 5 specimens to 5 out of 5 specimens having to pass the 25% or less requirement.

(Gabriel | California)

Reply: Others have noticed it as well and in response both peel separation and shear elongation will go to 5 out of 5. In earlier versions we were silent on these two items and then (foolishly) went to 4 out of 5 as in strength, but had “our ears pinned back.” The revised 5 out of 5 is now in place.

Bob Koerner | GMA Techline

Share this Story

Leave a Reply