Question
Can you please tell me Std-OIT and HP-OIT for a pure unstabilized PP resin?
Answer
The HP-OIT test is preferred for long-term antioxidants that are sensitive to the high temperature of melting in the Std-OIT test. For unstabilized PP and PE, the situation does not arise and therefore the Std-OIT test should be adequate … Bob K.
Dr. Robert Koerner, GSI and GMA Techline